RTLS live · 2s
Fleet overview
4,812 active devices across 31 care units · last sync 09:41:06
Fleet uptime · 90d
99.21%
Target 99.00% · +0.14 pts vs prior 90d
PM compliance
96.4%
1,284 of 1,332 on time
Open work orders
137
22 high-risk · 9 > SLA
Recall exposure
64units
3 open notices · 148 fixed
Mean time to repair
6.8h
Life-support: 3.1 h
Unlocated > 24h
41
0.85% of RTLS-tagged
Uptime trend
All devicesLife-support classJoint Commission floor
Needs attention
5All alerts
Class I recall — Infusa LX-4 firmware 3.2
64 pumps still unremediated · 11 in 4 West Cardiac ICU
Vento 880 · VNT-880-11472 failed self-test
O₂ cell drift 4.2% · pulled from 4 West Rm 408
9 PMs overdue on high-risk equipment
Defibrillators ×5, ventilators ×3, ECMO ×1
Par breach — 6 West NICU syringe pumps
7 of 12 on unit · nearest spares in Central Supply B2
Oriel Axion 128 CT service contract renews
Oct 31 · 97.6% uptime vs 98.5% SLA — credit owed
Fleet mosaic
In useIdlePM dueRecallOut of service
Corvane Infusa LX-4 · Large-volume infusion pump
In service · recall pending57%
Location
Specifications
- Manufacturer
- Corvane Medical
- Model
- LX-4 / REF 88104
- In service since
- 2022-02-14
- Expected life
- 10 yr · 57% used
- Contract
- Corvane Assure Plus
- Drug library
- NRG-ICU v2026.08
PM schedule
Sep29
Firmware 3.4.1 · recall remediation
Est. 25 min · requires pump swap on unit
Dec03
Battery capacity test
Semi-annual · 45 min
Jun02
Annual PM + electrical safety
IEC 62353 · 1.5 h
Battery health
5h 12m
Service log
12 entries
| WO-26-03318 | Annual PM | 1.4 h |
| WO-25-11902 | Door latch replaced | 0.6 h |
| WO-25-07714 | Keypad membrane | 2.1 h |
Recalls & safety notices
Auto-matched against 4,812 serials from FDA, MHRA and manufacturer feeds
Open notices
Class IPN-2026-0418Sep 24
Infusa LX-4 — occlusion alarm delay at low rates, firmware 3.2.x
212 matched · 69.8% remediated
Class IIFSN-HV-2611Sep 09
Vento 880 — O₂ sensor cell drift beyond ±3% after 18 months
38 matched · 84% remediated
Class IIPN-2026-0371Aug 18
Brightline PM-12 — battery pack swelling, lot BP-2291
64 matched · 92% remediated
AdvisorySA-KY-0092Aug 02
SonoView E7 — probe cleaning guidance update
17 matched · acknowledgement only
Live locations
East Tower · Level 4 · 4 West Cardiac ICU & 4 East Step-down · 318 tagged devices on floor
In useIdlePM / recallOut of serviceUpdated 09:41:06
Rm 412 · Bay A
Brightline PM-12BPM-12-77410
Infusa LX-4 ×2…20877 · …21302
Par levels · 4 West
Infusion pumps38 / par 34
Syringe pumps9 / par 12
Transport monitors6 / par 4